It is possible to find out which controller is failed via CLI (same can be done in CV as well).
C:\Program Files\Hewlett-Packard\Sanworks\Element Manager for StorageWorks HSV>.\cvutil paths
Status ……………………….. done.
Path Vendor Product Firmware Node Serial SCMI Master
WWN Number State
—————– —— —————- ——– ——————- ————– —– ——
\\.\Scsi3:-0-9-0 COMPAQ HSV111 (C)COMPAQ 4100 5000-1FE1-5003-CCF0 P5849E1AAQX0AF Ready Master
\\.\Scsi4:-0-7-0 COMPAQ HSV111 (C)COMPAQ 4100 5000-1FE1-5003-CCF0 P5849E1AAQX0AF Ready Master
\\.\Scsi3:-0-12-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D290 P5849D4AAOV00S n/a Slave
\\.\Scsi4:-0-12-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D290 P5849D4AAOV00S n/a Slave
\\.\Scsi3:-0-1-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D290 P5849E1AAQX03K n/a Master
\\.\Scsi4:-0-0-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D290 P5849E1AAQX03K n/a Master
\\.\Scsi3:-0-7-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D600 P5849E1AAQX06H n/a Slave
\\.\Scsi4:-0-5-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D600 P5849E1AAQX06H n/a Slave
\\.\Scsi4:-0-11-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D600 P5849E1AAQX06W n/a Master
\\.\Scsi3:-0-10-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D600 P5849E1AAQX06W n/a Master
\\.\Scsi3:-0-13-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D660 P5849E1AAQX03O n/a Master
\\.\Scsi4:-0-13-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D660 P5849E1AAQX03O n/a Master
\\.\Scsi4:-0-2-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D660 P5849E1AAQX068 n/a Slave
\\.\Scsi3:-0-3-0 COMPAQ HSV111 (C)COMPAQ 3010 5000-1FE1-5003-D660 P5849E1AAQX068 n/a Slave
Output shown above shows 4 EVAs (ending with CCF0, D290, D600, D660). All but CCF0 have 4 lines which indicates CCF0 has one controller down.
No comments yet.